Titan II
For telecommunications applications
 
Sageon Titan II
  Product Resources
Literature
  #10-1023 Titan II 208/7200 Bulk Power System
(PDF 417KB)
  #10-1024 Titan II 480/7200 Bulk Power System
(PDF 450KB)
  #10-1025 Titan II 208/7200 Distribution Power System
(PDF 325KB)
  #10-1026 Titan II 480/7200 Distribution Power System
(PDF 326KB)
Product Manual
  Titan II Installation, Operation and Maintenance Manual (PDF 4.3MB)
  Titan II BDFB Product Manual (PDF 1.402MB)
  Titan II RMS and Web Manual (PDF 1.62MB)
Select Product
  Contact your local Representative
Related Products
 

#10-1022 Titan II 7200 Rectifier
(PDF 299KB)

 

The Titan II is a true three phase power system with distribution that will support 480/208/240 VAC input requirements. The Titan II Power System consists of modular rectifiers, rectifier bays, modular distribution bays, and a Control and Supervisory Unit (CSU). Up to twelve Titan II 7200 rectifiers can be installed in each rectifier bay and up to seven (7) rectifier bays with one (1) primary distribution bay and three (3) secondary distribution bays can be installed in a single system. The rectifiers provide a nominal output of -54.2 VDC to power DC loads and maintain fully charged batteries.

The system is monitored and controlled by the CSU which is mounted in the primary rectifier bay (bulk systems) or in the primary distribution bay (systems with DC distribution). Rectifier/system status, voltage and current settings, and alarms are all viewed/modified at the CSU. The CSU also has an interface to the Remote Monitoring System (RMS) software package used for remote or local monitoring and control via a laptop computer or serial transmission to a workstation. Remote monitoring can also be accomplished over the network via a webpage and/or integral SNMP client.

Applications

  • Telecom central offices
  • Data centers
  • Ferro-replacement

Rectifier Features

  • Constant rectifier power output, 7200W per rectifier
  • Low THD, high efficiency
  • Hot-swappable
  • 208/240 or 480 Vrms input (phase to phase), wide input range
  • Integrated breaker/fuse protection
  • Individual back-lit LCD status display

System Features

  • Individual (per rectifier) AC feed or Single (per bay) AC feed
  • Back-lit LCD CSU display
  • DC Distribution via GJ1 type breakers, or TPL fuses
  • Up to 10,000 Amps of system capacity
  • Configurable monitoring and alarming
  • Up to 20 user configurable alarm relay outputs (10 for bulk systems)
  • Up to 8 "relay closure" user inputs (4 for bulk systems)
  • Remote monitoring via webpage and SNMP

Return